Hoyme 'HAE' Motorless Air Exchanger
FURNACE FAN DOES IT ALL!
Building codes require outside
fresh air to be supplied into a dwelling and for the sake of comfort, this air
is to be tempered. HOYME Motorless Air Exchanger (HAE) does this and more. It
also tempers cold air before it enters the area of the furnace fan and
therefore protects furnace parts. No need for expensive electric heaters or
special motors to service or wear out. With the HAE, there are no moving
parts, the furnace fan does it all. Using the furnace fan also guarantees the
HAE remains operational at all times.
While
fresh, warm air is supplied through the Air Exchanger into the heating system,
moist stale air is exhausted through a separate duct. The exchange of air,
according to calculations, is approximately 100 to 120 cu. ft/minute,
depending on the static pressure of the furnace fan. The area of heat transfer
in the unit is over 3000 sq.in. plus another 3000 sq.in. when using at least a
total of 15 ft. of concentric ducting connected to and from the unit. As a
result, heat transfer proves to be very high as shown in test reports. e.q.
Outside temperature of -30 C (-22F) enters the return plenum at +14 C (+57 F).
This incoming air is preheated solely by the heat transfer of exhausting air
and therefore receiving warm fresh air at minimum cost.
The
exhausting of stale, moist air while the furnace is firing defrosts any ice
build-up in the unit with the extra heat being brought back into the system.
Excess moisture is drained off through a plastic hose directed to a drain.
Multiple 2" diameter aluminum ducts inside the unit eliminate plugging and
therefore guarantee a continual flow of fresh inlet air and a continual
exhausting of moist stale air through all kinds of weather. Exhaust fans
from bathrooms, kitchens and other areas can also be directed through the HAE
unit by the addition of an optional kit having a back-draft damper and a
'Y' connection.
THE
HAE-2000-100' unit is 14" x 13" x 52" and handles up to 120 cu.ft./min. The
'HAE-2000-200' unit is 14" x 16" x 52" and handles up to 220 cu.ft./min. Both
units come with; Double intake/exhaust hood, 8" and 5" diameters for the '100'
size and 9" and 5" for the '200' size; Double return/supply plenum connector,
8" and 5" diameters or 9" and 5" diameters; Balance manual damper, 5"diameter;
4' of silver flex, 5" diameter; metal hanger brackets and 15' of 1/2" plastic
drain hose. Installer to supply 5" dia. and 8" dia. flex ducting as required. Satisfaction
is guaranteed.
The
regular commercial 'HAE-2000-500' is 14" x 23" x 100" and handles up to 500
cu.ft./min. This unit has two 8" dia. intakes and two 8" dia. exhaust ports
projecting out both ends. C/W 15' of 1/2" plastic drain hose and four metal
hanger brackets. Installer to supply 8" dia. ducting, two all-weather hoods,
manual balancing damper and other necessary connectors for intake and exhaust.
Fans may also be necessary if not connecting to a forced air heating system.
|